SERVICE BULLETIN Issued by Canon Europa N.V. FAX MODEL: LaserBase MF5650 No.: MF5650-001 (SH-T01-0LD-10011-01) Date: 30.07.04 SUBJECT: PROBLEMS OCCURRING WHEN TRANSMISSION HAS BEEN MADE FROM LASERBASE MF5650 TO TIS-MADE PRODUCT DESTINATION: F14-5692 (UK, GER, FRN, EUR) Detail: <Symptom> The following problems occur on the LCD of UA1612 (model name) and the communication control report when transmission has been made from LaserBase MF5650 to TIS (manufacturer)-made UA1612. LCD: The square mark appears continuously following numbers displayed on the LCD of UA1612 (reception side). (Up to the 20th digit counted from the first number.) e.g.) 12-3456: 123456 …… Communication control report: The last number of numbers in the communication control report of UA1612 (reception side) appears continuously. (Up to the 20th digit counted from the first number.) e.g.) 12-3456: 123456666...... <Cause> Software bug. <Sidestepping Method> Enter spaces up to the 20th digit (counted from the first number) following valid numbers. <Factory Measure> Countermeasures will be taken to software in late July.